Foundry Equipment

Sample Preparation

Model MSL HC

BLOWER SPECIMEN APPARATUS

Blow and cures specimens of hot box and cold box mixes

SPECIFICATIONS

  • Digitals controls:
    – cure timer range: 0 – 99,9 sec.
    – blow timer range: 0 – 9,99 sec.
    – air purge timer range: 0 – 99,9 sec.
    – cure temperature range: 0-450,0 C
    – amine gas temperature range: 0-90,0 C
  • Controls the pressure blow
  • Controls the pressure and flow of amine gas
  • Graduated burette for amine gas
  • Compressed air required: 4 – 6 bar (56 – 85 psi)
  • Power requirements: 230 V / 50-60 Hz
  • Weight: 48 kg ( 106 lb)
  • Includes a Tensile box
  • Range: One Specimen
PROCESS OF SAND MOLD AND CORE SAND TESTS EQUIPMENTS (MODELS)
PERFORMS THE TEST ACCESSORIES AUXILIARY ESPECIMEN PREPARATION
HOT-BOX MIXES SANDS TENSILE STRENGTH DAP AD03 MSL HB or HC
TRANSVERSE STRENGTH DAP AD02 MSL HB or HC
CORE PERMEABILITY PER AP02 MSL HB or HC
COLD BOX MIXES SANDS TENSILE STRENGTH DAP AD03 MSL CB or HC
TRANSVERSE STRENGTH DAP AD02 MSL CB or HC
CORE PERMEABILITY PER AP02 MSL CB or HC